Proofex Torchseal A800 FC007016-UNIT

Proofex Torchseal A800 FC007016-UNIT
  • Proofex Torchseal A800 FC007016-UNIT

Proofex Torchseal A800

Torch applied 4mm thick, reinforced elastoplastomeric polymer - bitumen waterproofing membrane used as a continuous waterproofing membrane for foundations, basements and tunnels.

Typical Applications

  • Waterproofing of foundations, basements, tunnels, terraces and roofs

Advantages

  • APP polymer modified -specifically selected for Australian conditions
  • Handles ponding and permanently wet conditions
  • No curing times. Instantly waterproof
  • Uniform thickness eliminating likelihood of uneven application possible with liquid applied membranes
  • Excellent stability at both high and low temperatures
  • Excellent durability and flexibility
  • Flexibility at low temperature (EN1109) : -15°C
  • Impermeability to water (EN1928 B method) : ≥ 60 kPa
  • Longitudinal Tensile elongation (EN12311 1) : 45%
  • Longitudinal Tensile strength (EN12311 1) : 700 N/50mm
  • Thickness /Mass : 4mm
  • Transverse Tensile elongation (EN12311 1) : 45%
  • Transverse Tensile strength (EN12311 1) : 600 N/50mm
Vertical Downward Termination (b) Pressure Seal Drainage Detail for an Exposed Membrane Below Ground Tanking-Typical Edge Detail Edge Protection of Sheet Membrane over a Parapet Detail of Horizontal Membrane Penetration Detail Metal Support - Before Membrane Installation Detail Metal Post Support - After Sheet Membrane Installation Overflow Pipe through Parapet Detail (b) Pre-Formed Spitter through Parapet Overflow Pipe through Parapet Detail (c) Pre-Formed Spitter Placed at Corner to Parapet Planter Box Construction Details One Way Movement Joint Detail Typical Continuous Movement Joint Vertical Upward Termination Pressure Seal Torchseal Vertical Upward Termination Overflashing - Torchseal UV Exposed Roof Parapet-Deck (a) Bituminous Sheet Membrane System UV Exposed Roof Podium Deck (b) Membrane as Documented UV Exposed Roof Podium Deck (a) Bituminous Sheet Membrane System Insulated Roof Podium Deck (a) IRMA Bituminous Sheet Membrane System Insulated Roof Podium Deck Torchseal Membrane System Landscaped Roof Podium Deck (b)-Bituminous Sheet Membrane System Water-Retaining Lap Joint for Sheet Membrane-Details Roof Podium Deck System for Wet Substrate Ventilation Roof Podium Deck Membrance System for Heat Sensitive Substrates Typical Construction Joint Detail for 2 Layer Bituminous Sheet Membrane Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (a) Pressure Seal Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (b) Overflashing Edge Protection of Sheet Membrane Over Parapet Horizontal Membrane Termination Typical Detail 2 Layer Bituminous Membrane System Trafficable Roof Podium Deck (a) Bituminous Sheet Membrane System Trafficable Roof Podium Deck (b) Membrane as Documented System Landscaped Roof Podium Deck (a) Bituminous Sheet Membrane System Water Shedding

Overview

Typical Applications

  • Waterproofing of foundations, basements, tunnels, terraces and roofs

Advantages

  • APP polymer modified -specifically selected for Australian conditions
  • Handles ponding and permanently wet conditions
  • No curing times. Instantly waterproof
  • Uniform thickness eliminating likelihood of uneven application possible with liquid applied membranes
  • Excellent stability at both high and low temperatures
  • Excellent durability and flexibility

Key Properties

  • Flexibility at low temperature (EN1109) : -15°C
  • Impermeability to water (EN1928 B method) : ≥ 60 kPa
  • Longitudinal Tensile elongation (EN12311 1) : 45%
  • Longitudinal Tensile strength (EN12311 1) : 700 N/50mm
  • Thickness /Mass : 4mm
  • Transverse Tensile elongation (EN12311 1) : 45%
  • Transverse Tensile strength (EN12311 1) : 600 N/50mm

Spec Clause

Detail Drawing

Vertical Downward Termination (b) Pressure Seal Drainage Detail for an Exposed Membrane Below Ground Tanking-Typical Edge Detail Edge Protection of Sheet Membrane over a Parapet Detail of Horizontal Membrane Penetration Detail Metal Support - Before Membrane Installation Detail Metal Post Support - After Sheet Membrane Installation Overflow Pipe through Parapet Detail (b) Pre-Formed Spitter through Parapet Overflow Pipe through Parapet Detail (c) Pre-Formed Spitter Placed at Corner to Parapet Planter Box Construction Details One Way Movement Joint Detail Typical Continuous Movement Joint Vertical Upward Termination Pressure Seal Torchseal Vertical Upward Termination Overflashing - Torchseal UV Exposed Roof Parapet-Deck (a) Bituminous Sheet Membrane System UV Exposed Roof Podium Deck (b) Membrane as Documented UV Exposed Roof Podium Deck (a) Bituminous Sheet Membrane System Insulated Roof Podium Deck (a) IRMA Bituminous Sheet Membrane System Insulated Roof Podium Deck Torchseal Membrane System Landscaped Roof Podium Deck (b)-Bituminous Sheet Membrane System Water-Retaining Lap Joint for Sheet Membrane-Details Roof Podium Deck System for Wet Substrate Ventilation Roof Podium Deck Membrance System for Heat Sensitive Substrates Typical Construction Joint Detail for 2 Layer Bituminous Sheet Membrane Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (a) Pressure Seal Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (b) Overflashing Edge Protection of Sheet Membrane Over Parapet Horizontal Membrane Termination Typical Detail 2 Layer Bituminous Membrane System Trafficable Roof Podium Deck (a) Bituminous Sheet Membrane System Trafficable Roof Podium Deck (b) Membrane as Documented System Landscaped Roof Podium Deck (a) Bituminous Sheet Membrane System Water Shedding