Proofex Torchseal A625 FC007014-UNIT

Proofex Torchseal A625 FC007014-UNIT
  • Proofex Torchseal A625 FC007014-UNIT

Proofex Torchseal A625

Torch applied 4.5mm thick, mineral finish, reinforced polymer - bitumen waterproofing membrane. Used as the top layer in a two layer membrane system or as a single roof membrane.

Typical Applications

  • Used as the top layer in a two layer membrane system or as a single roof membrane for both new and renovation work

Advantages

  • APP polymer modified -specifically selected for Australian conditions
  • Handles ponding and permanently wet conditions
  • No curing times
  • Instantly waterproof
  • Uniform thickness eliminating likelihood of uneven application possible with liquid applied membranes
  • Excellent stability at both high and low temperatures
  • Excellent durability and flexibility
  • Mineral finish provides improved UV resistance
  • Flexibility at low temperature (EN1109) : -10°C
  • Impermeability to water (EN1928 B method) : ≥ 60 kPa
  • Longitudinal Tensile elongation (EN12311 1) : 40%
  • Longitudinal Tensile strength (EN12311 1) : 700 N/50mm
  • Thickness /Mass : 4.5mm
  • Transverse Tensile elongation (EN12311 1) : 45%
  • Transverse Tensile strength (EN12311 1) : 450 N/50mm
Vertical Downward Termination (b) Pressure Seal Below Ground Tanking-Typical Edge Detail Drainage Detail for an Exposed Membrane Detail of Horizontal Membrane Penetration Edge Protection of Sheet Membrane over a Parapet Detail Metal Support - Before Membrane Installation Detail Metal Post Support - After Sheet Membrane Installation Overflow Pipe through Parapet Detail (b) Pre-Formed Spitter through Parapet Overflow Pipe through Parapet Detail (c) Pre-Formed Spitter Placed at Corner to Parapet Planter Box Construction Details One Way Movement Joint Detail Typical Continuous Movement Joint Vertical Upward Termination Pressure Seal Torchseal Vertical Upward Termination Overflashing - Torchseal UV Exposed Roof Parapet-Deck (a) Bituminous Sheet Membrane System UV Exposed Roof Podium Deck (b) Membrane as Documented UV Exposed Roof Podium Deck (a) Bituminous Sheet Membrane System Insulated Roof Podium Deck (a) IRMA Bituminous Sheet Membrane System Insulated Roof Podium Deck Torchseal Membrane System Landscaped Roof Podium Deck (a) Bituminous Sheet Membrane System Water Shedding Landscaped Roof Podium Deck (b)-Bituminous Sheet Membrane System Water-Retaining Roof Podium Deck System for Wet Substrate Ventilation Roof Podium Deck Membrance System for Heat Sensitive Substrates Typical Construction Joint Detail for 2 Layer Bituminous Sheet Membrane Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (a) Pressure Seal Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (b) Overflashing Edge Protection of Sheet Membrane Over Parapet Horizontal Membrane Termination Typical Detail 2 Layer Bituminous Membrane System Trafficable Roof Podium Deck (a) Bituminous Sheet Membrane System Trafficable Roof Podium Deck (b) Membrane as Documented System Lap Joint for Sheet Membrane-Details

Overview

Typical Applications

  • Used as the top layer in a two layer membrane system or as a single roof membrane for both new and renovation work

Advantages

  • APP polymer modified -specifically selected for Australian conditions
  • Handles ponding and permanently wet conditions
  • No curing times
  • Instantly waterproof
  • Uniform thickness eliminating likelihood of uneven application possible with liquid applied membranes
  • Excellent stability at both high and low temperatures
  • Excellent durability and flexibility
  • Mineral finish provides improved UV resistance

Key Properties

  • Flexibility at low temperature (EN1109) : -10°C
  • Impermeability to water (EN1928 B method) : ≥ 60 kPa
  • Longitudinal Tensile elongation (EN12311 1) : 40%
  • Longitudinal Tensile strength (EN12311 1) : 700 N/50mm
  • Thickness /Mass : 4.5mm
  • Transverse Tensile elongation (EN12311 1) : 45%
  • Transverse Tensile strength (EN12311 1) : 450 N/50mm

Spec Clause

Detail Drawing

Vertical Downward Termination (b) Pressure Seal Below Ground Tanking-Typical Edge Detail Drainage Detail for an Exposed Membrane Detail of Horizontal Membrane Penetration Edge Protection of Sheet Membrane over a Parapet Detail Metal Support - Before Membrane Installation Detail Metal Post Support - After Sheet Membrane Installation Overflow Pipe through Parapet Detail (b) Pre-Formed Spitter through Parapet Overflow Pipe through Parapet Detail (c) Pre-Formed Spitter Placed at Corner to Parapet Planter Box Construction Details One Way Movement Joint Detail Typical Continuous Movement Joint Vertical Upward Termination Pressure Seal Torchseal Vertical Upward Termination Overflashing - Torchseal UV Exposed Roof Parapet-Deck (a) Bituminous Sheet Membrane System UV Exposed Roof Podium Deck (b) Membrane as Documented UV Exposed Roof Podium Deck (a) Bituminous Sheet Membrane System Insulated Roof Podium Deck (a) IRMA Bituminous Sheet Membrane System Insulated Roof Podium Deck Torchseal Membrane System Landscaped Roof Podium Deck (a) Bituminous Sheet Membrane System Water Shedding Landscaped Roof Podium Deck (b)-Bituminous Sheet Membrane System Water-Retaining Roof Podium Deck System for Wet Substrate Ventilation Roof Podium Deck Membrance System for Heat Sensitive Substrates Typical Construction Joint Detail for 2 Layer Bituminous Sheet Membrane Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (a) Pressure Seal Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (b) Overflashing Edge Protection of Sheet Membrane Over Parapet Horizontal Membrane Termination Typical Detail 2 Layer Bituminous Membrane System Trafficable Roof Podium Deck (a) Bituminous Sheet Membrane System Trafficable Roof Podium Deck (b) Membrane as Documented System Lap Joint for Sheet Membrane-Details

Fact Sheet

Brochures

Technical Data Sheet

Proofex Torchseal A625 TDS

Safety Data Sheet

Proofex Torchseal A625 SDS