Self-adhesive 3 mm thick base sheet for heat sensitive substrates in multilayered torch on bitumen membrane systems

Typical Applications

  • Base layer in multi-layer torch applied waterproofng systems being applied to heat sensitive substrates such as

Advantages

  • Handles ponding and permanently wet conditions
  • No curing times. Instantly waterproof
  • Self adhesive membrane, no need to flame adhere base sheet to substrate
  • Flexibility at low temperature (EN1109) : -15°C
  • Impermeability to water (EN1928 B method) : >60 kPa
  • Longitudinal Tensile elongation (EN12311 1) : 40%
  • Longitudinal Tensile strength (EN12311 1) : 450 N/50mm
  • Thickness /Mass : 3mm
  • Transverse Tensile elongation (EN12311 1) : 45%
  • Transverse Tensile strength (EN12311 1) : 350 N/50mm
Vertical Downward Termination (b) Pressure Seal Drainage Detail for an Exposed Membrane Below Ground Tanking-Typical Edge Detail Edge Protection of Sheet Membrane over a Parapet Detail of Horizontal Membrane Penetration Detail Metal Support - Before Membrane Installation Detail Metal Post Support - After Sheet Membrane Installation Overflow Pipe through Parapet Detail (b) Pre-Formed Spitter through Parapet Overflow Pipe through Parapet Detail (c) Pre-Formed Spitter Placed at Corner to Parapet Planter Box Construction Details One Way Movement Joint Detail Typical Continuous Movement Joint Vertical Upward Termination Pressure Seal Torchseal Vertical Upward Termination Overflashing - Torchseal UV Exposed Roof Parapet-Deck (a) Bituminous Sheet Membrane System UV Exposed Roof Podium Deck (b) Membrane as Documented UV Exposed Roof Podium Deck (a) Bituminous Sheet Membrane System Insulated Roof Podium Deck (a) IRMA Bituminous Sheet Membrane System Insulated Roof Podium Deck Torchseal Membrane System Landscaped Roof Podium Deck (a) Bituminous Sheet Membrane System Water Shedding Landscaped Roof Podium Deck (b)-Bituminous Sheet Membrane System Water-Retaining Roof Podium Deck System for Wet Substrate Ventilation Roof Podium Deck Membrance System for Heat Sensitive Substrates Typical Construction Joint Detail for 2 Layer Bituminous Sheet Membrane Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (a) Pressure Seal Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (b) Overflashing Edge Protection of Sheet Membrane Over Parapet Horizontal Membrane Termination Typical Detail 2 Layer Bituminous Membrane System Trafficable Roof Podium Deck (b) Membrane as Documented System Lap Joint for Sheet Membrane-Details Trafficable Roof Podium Deck (a) Bituminous Sheet Membrane System

Overview

Typical Applications

  • Base layer in multi-layer torch applied waterproofng systems being applied to heat sensitive substrates such as

Advantages

  • Handles ponding and permanently wet conditions
  • No curing times. Instantly waterproof
  • Self adhesive membrane, no need to flame adhere base sheet to substrate

Key Properties

  • Flexibility at low temperature (EN1109) : -15°C
  • Impermeability to water (EN1928 B method) : >60 kPa
  • Longitudinal Tensile elongation (EN12311 1) : 40%
  • Longitudinal Tensile strength (EN12311 1) : 450 N/50mm
  • Thickness /Mass : 3mm
  • Transverse Tensile elongation (EN12311 1) : 45%
  • Transverse Tensile strength (EN12311 1) : 350 N/50mm

Spec Clause

Detail Drawing

Vertical Downward Termination (b) Pressure Seal Drainage Detail for an Exposed Membrane Below Ground Tanking-Typical Edge Detail Edge Protection of Sheet Membrane over a Parapet Detail of Horizontal Membrane Penetration Detail Metal Support - Before Membrane Installation Detail Metal Post Support - After Sheet Membrane Installation Overflow Pipe through Parapet Detail (b) Pre-Formed Spitter through Parapet Overflow Pipe through Parapet Detail (c) Pre-Formed Spitter Placed at Corner to Parapet Planter Box Construction Details One Way Movement Joint Detail Typical Continuous Movement Joint Vertical Upward Termination Pressure Seal Torchseal Vertical Upward Termination Overflashing - Torchseal UV Exposed Roof Parapet-Deck (a) Bituminous Sheet Membrane System UV Exposed Roof Podium Deck (b) Membrane as Documented UV Exposed Roof Podium Deck (a) Bituminous Sheet Membrane System Insulated Roof Podium Deck (a) IRMA Bituminous Sheet Membrane System Insulated Roof Podium Deck Torchseal Membrane System Landscaped Roof Podium Deck (a) Bituminous Sheet Membrane System Water Shedding Landscaped Roof Podium Deck (b)-Bituminous Sheet Membrane System Water-Retaining Roof Podium Deck System for Wet Substrate Ventilation Roof Podium Deck Membrance System for Heat Sensitive Substrates Typical Construction Joint Detail for 2 Layer Bituminous Sheet Membrane Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (a) Pressure Seal Roof Podium Deck Waterproofing Typical Vertical Upward Termination Detail (b) Overflashing Edge Protection of Sheet Membrane Over Parapet Horizontal Membrane Termination Typical Detail 2 Layer Bituminous Membrane System Trafficable Roof Podium Deck (b) Membrane as Documented System Lap Joint for Sheet Membrane-Details Trafficable Roof Podium Deck (a) Bituminous Sheet Membrane System